TitleProduct

Indoor Type of Impulse Generator

  • Price:

    Negotiable

  • minimum:

  • Total supply:

  • Delivery term:

    The date of payment from buyers deliver within days

  • seat:

    Beijing

  • Validity to:

    Long-term effective

  • Last update:

    2021-10-13 17:23

  • Browse the number:

    208

Send an inquiries

Company Profile

Beijing Hua Tian Mechanical-Electrical Institute Co., Ltd

By certification [File Integrity]

Contact:huatianjidian(Mr.)  

Email:

Telephone:

Phone:

Area:Beijing

Address:Beijing

Website:http://www.bhthv.com/ http://huatianjidian.shaodejx.com/

PRODUCT DETAILS

H-type structure impulse voltage generator

Type H impulse voltage generator With its features of high voltage grade, high capacity and strong load ability, Applicable to the impulse insulation withstand test of high-voltage electrical products such as high-voltage transformers, switches, cables, reactors, insulators etc. and The test of high voltage equipment manufacturers


Scope of Application

Specification & Model

Rated Voltage (kV)

Total Energy (kJ)

Main Capacitance (μF)

Stage Voltage (kV)

No.of Stages (n)

Height (m)

CDYH1400kV

1400

70~210

0.071~0.21

200

7

6.0

CDYH1600kV

1600

80~240

0.063~0.188

200

8

6.6

CDYH1800kV

1800

90~270

0.056~0.167

200

9

7.3

CDYH2000kV

2000

100~300

0.05~0.15

200

10

7.8

CDYH2200kV

2200

110~330

0.045~0.136

200

11

8.4

CDYH2400kV

2400

120~360

0.042~0.125

200

12

9.3

CDYH2800kV

2800

140~420

0.036~0.107

200

14

10.8

CDYH3000kV

3000

150~450

0.033~0.1

200

15

11.4

CDYH3200kV

3200

160~480

0.031~0.094

200

16

12.0

CDYH3600kV

3600

180~540

0.028~0.083

200

18

13.4

CDYH4000kV

4000

200~600

0.025~0.075

200

20

14.8

CDYH4200kV

4200

200~600

0.023~0.068

200

21

15.5

CDYH4800kV

4800

240~720

0.021~0.063

200

23

17.3

CDYH6000kV

6000

450~1350

0.025~0.075

300

20

21.3

CDYH7200kV

7200

540~1620

0.021~0.063

300

24

25.4


L-shaped structure impulse voltage generator

Type L impulse voltage generator With its features of compact structure, low loop inductance and easy-to-modulate wave, Applicable to the impulse insulation withstanding test of high-voltage electrical products such as low-voltage transformers, switches, cables, reactors, insulators etc. and The test of high voltage equipment manufacturers


Scope of Application

Specification & Model

Rated Voltage (kV)

Total Energy (kJ)

Main Capacitance (μF)

Stage Voltage (kV)

No.of Stages (n)

Height (m)

CDYL100kV

100

2.5~7.5

0.5~1.5

100

1

1.1

CDYL200kV

200

5~15

0.25~0.75

100

2

1.5

CDYL300kV

300

7.5~22.5

0.167~0.5

100

3

1.8

CDYL400kV

400

10~30

0.125~0.375

100

4

2.3

CDYL500kV

500

12.5~37.5

0.1~0.3

100

5

2.8

CDYL600kV

600

15~45

0.083~0.25

100

6

3.2

CDYL700kV

700

17~53

0.071~0.214

100

7

3.6

CDYL800kV

800

20~60

0.063~0.188

100

8

4.0

CDYL900kV

900

22.5~67.6

0.056~0.167

100

9

4.4

CDYL1000kV

1000

25~75

0.05~0.15

100

10

4.7

CDYL1200kV

1200

45~135

0.063~0.188

150

8

5.1


http://www.bhthv.com/